Command introduced before Junos OS Release 7.4.
Start a bit error rate test (BERT) on a DS0 interface.
ds-fpc/pic/port | — | DS0 interface name. |
Before starting a BERT, you must disable the interface. To do so, include the disable statement at the [edit interfaces interface-name] hierarchy level. You can run a BERT on only one interface per PIC at a time.
view
To display the results of the BERT, use the show interfaces extensive command.
test interface ds0-bert-start
user@host> test interface ds0-bert-start ds-1/0/0