symbol-period
Syntax
Hierarchy Level
- [edit protocols oam ethernet link-fault-management event, link-event-rate],
- [edit protocols oam link-fault-management interface-name event-thresholds]
Release Information
Statement introduced in JUNOS Release 8.4.
Description
Configure the threshold for sending symbol period events or taking the action specified in the action profile.
A symbol error is any symbol code error on the underlying physical layer. The symbol period threshold is reached when the number of symbol errors reaches the configured value within the period window. The default period window is the number of symbols that can be transmitted on the underlying physical layer in 1 second. The window is not configurable.
Options
-
count—Threshold count for symbol period events.
- Range: 1 through 100
Usage Guidelines
See Configuring Threshold Values for Local Fault Events on an Interface and Configuring Threshold Values for Fault Events in an Action Profile.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.