maintenance-domain
Syntax
- maintenance-domain domain-name {
- bridge-domain name;
- instance vpls-instance;
- level number;
- mip-half-function (none | default | explicit);
- name-format (character-string
| none | dns | mac+2oct);
-
- maintenance-association ma-name {
- short-name-format (character-string | vlan | 2octet | rfc-2685-vpn-id);
-
- continuity-check {
- hold-interval (OAM) minutes;
- interval (10m |
10s | 1m | 1s| 100ms);
- loss-threshold number
- }
-
- mep mep-id {
- action-profile profile-name;
- auto-discovery;
- direction (up |
down);
- interface interface-name;
- priority number;
-
- remote-mep mep-id {
- action-profile profile-name;
- }
- }
- mip-half-function(none | default | explicit);
- }
-
- routing-instance name {
- bridge-domain name;
- }
- virtual-switch name bridge-domain name;
- }
Hierarchy Level
- [edit protocols oam ethernet connectivity-fault-management]
Release Information
Statement introduced in JUNOS Release 8.4.
Description
Configure the name of the maintenance domain in IEEE-compliant format.
Options
-
domain-name—The name for the maintenance domain.
-
The remaining statements are explained separately.
Usage Guidelines
See Creating the Maintenance Domain and Example: Configuring Connectivity Fault Management for a PBB Network on MX Series Routers.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.