Example of a Router Receiving Only an RDI-P Alarm
Problem
Figure 17 shows a router receiving only an RDI-P Alarm. The X indicates that the LOS or LOF occurs in the section between ADM 1 and ADM 2.
Solution
All diagnostics are from the perspective of Router 2 (the Juniper Networks router).
Figure 17: Example of a Router Receiving Only an RDI-P Alarm

What It Means
In Figure 17, the progression of events occurring after the failure is as follows:
- ADM 1 detects an LOS or LOF on an incoming SONET section.
- ADM 1 sends an RDI-L to ADM 2.
- ADM 1 sends an AIS-P downstream to Router 1.
- Router 1 sends an RDI-P upstream to Router 2.
- Router 2 only receives an RDI-P alarm.