List of Common SONET Alarms and Errors
Purpose
To check for the most common SONET alarms and errors you can encounter when investigating line problems on a Juniper Networks router.
Action
Table 30 provides links and commands for checking SONET alarms and errors.
Table 30: List of Common SONET Alarms and Errors
Tasks | Command or Action |
|---|---|
| Display SONET Alarms and Errors | show interfaces so-fpc/pic/port extensive |
| Locate Most Common SONET Alarms and Errors | |
Check the connection between the router port and the first SONET network element. | |
Downstream from the router, check the path-terminating equipment, section-terminating equipment, and line-terminating equipment for a loss of signal or loss of frame. | |
Upstream from the router, check the path-terminating equipment, section-terminating equipment, and line-terminating equipment for a loss of signal or loss of frame. | |
Upstream from the router, check the line-terminating equipment and path-terminating equipment for an error in the B2 or B3 byte. | |
Check the following:
| |
Check the received and transmitted C2 byte. | |
Check that both sides of the connection are configured for concatenate or nonconcatenate mode. | |
Check provisioning with the SONET provider, and if possible, check the configuration of the add/drop multiplexer (ADM). | |
Investigate the timing source, and configure the clocking to external or internal depending on the situation. |
Related Documentation
- Display SONET Alarms and Errors
- Locate Most Common SONET Alarms and Errors
- Locate Loss of Signal Alarms
- Locate Alarm Indication Signal Alarms
- Locate Remote Defect Indication Alarms
- Locate Remote Error Indication Line Errors
- Locate Bit Error Rate Alarms
- Locate Payload Label Mismatch Path Alarms
- Locate Loss of Pointer Path Alarms
- Locate Unequipped Payload Alarms
- Locate Phase Lock Loop Alarms
Hide Navigation Pane