EX2200/EX2200-C
EX3200
EX3300
EX4200
EX4300
EX4500/EX4550
EX6200
EX8200
EX9200
Form Factor
  • Fixed platform
  • Virtual Chassis configuration consisting of up to four switches
Fixed platform
  • Fixed platform
  • Virtual Chassis configuration consisting of up to 10 switches
  • Fixed platform
  • Virtual Chassis configuration consisting of 10 switches
  • Fixed platform
  • Virtual Chassis configuration consisting of 10 switches
  • Fixed platform
  • Virtual Chassis configuration consisting of up to 10 switches
10-slot modular chassis
  • EX8208: Eight-slot modular chassis
  • EX8216: 16-slot modular chassis
  • Virtual Chassis configuration consisting of up to four switches
  • EX9204: 4-slot modular chassis
  • EX9208: 8-slot modular chassis
  • EX9214: 14-slot modular chassis
Dimensions

EX2200:

  • (W x H x D) 17.4 x 1.7 x 10 in (44.1 x 4.4 x 25.4 cm)
  • 1 rack unit

EX2200-C:

  • (W x H x D) 10.6 x 1.7 x 9 in (26.9 x 4.4 x 22.8 cm)
  • 1 rack unit
  • (W x H x D) 17.4 x 1.7 x 16.4 in (44.2 x 4.3 x 41.7 cm)
  • 1 rack unit
  • (W x H x D) 17.4 x 1.7 x 12 in (44.1 x 4.3 x 31 cm)
  • 1 rack unit
  • (W x H x D) 17.4 x 1.7 x 16.4 in (44.2 x 4.3 x 41.7 cm)
  • 1 rack unit
  • (W x H x D) 17.4 x 1.7 x 16.4 in
    (44.2 x 4.3 x 41.7 cm)
  • 1 rack unit
EX4500:
  • (W x H x D) 17.3 in x 3.5 in x 21.1 in (43.8 cm x 8.9 cm x 53.6 cm)
  • 2 rack units
EX4550:
  • (W x H x D) 17.4 in x 1.7 in x 18.5 in (44.07 cm x 4.4 cm x 47.0 cm)
  • 1 rack unit
  • (W x H x D) 17.3 x 24.3 x 15.5 in (43.9 x 61.7 x 39.4 cm)
  • 14 rack unit
EX8208:
  • (W x H x D) 17.25 x 24.25 x 21 in (43.82 x 61.6 x 53 cm)
  • 14 rack units
EX8216:
  • (W x H x D) 17.3 x 36.5 x 26.5 in (43.9 x 92.7 x 67.4 cm)
  • 21 rack units
EX9204
  • (W x H x D): 17.5 x 8.7 x 27.8 in (44.5 x 22.1 x 70.5 cm)
  • 5 rack units
EX9208
  • (W x H x D): 17.5 x 14 x 27.8 in (44.5 x 35.6 x 70.5 cm)
  • 8 rack units
EX9214
  • (W x H x D): 17.5 x 27.8 x 27.8 in (44.5 x 70.5 x 70.5 cm)
  • 16 rack units
Backplane SpeedN/AN/A40-80 Gbps128 Gbps (Virtual Chassis)320 Gbps (Virtual Chassis)
  • EX4500: Up to 128 Gbps (Virtual Chassis)
  • EX4550: Up to 256 Gbps (Virtual Chassis)
4.4 Tbps backplane capacity
  • 320 Gbps (full duplex) per line card with current switch fabric
  • 6.2 Tbps (EX8208) or 12.4 Tbps (EX8216) per chassis
  • EX9204: Up to 1.6 Tbps per chassis
  • EX9208: Up to 4.8 Tbps per chassis
  • EX9214: Up to 13.2 Tbps per chassis
Data Rate
  • EX2200-24P/24T: 56 Gbps
  • EX2200-48P/48T: 104 Gbps
  • EX2200-C-12T/12P-2G:
    28 Gbps
    EX3200-24P/24T: 88 Gbps
    EX3200-48P/48T: 136 Gbps
  • EX3300-24P/24T/24T-DC:
    128 Gbps
  • EX3300-48P/48T/48T-BF:
    176 Gbps
EX4200-24P/24T/24F: 88 Gbps
EX4200-48P/48T: 136 Gbps
EX4300-24P/24T: 448 Gbps
EX4300-48P/48T: 496 Gbps
EX4300-32F: 464 Gbps
960 Gbps (full duplex)
  • 128 Gbps (full duplex) per linecard with two SREs installed
  • 64 Gbps (full duplex) per linecard with one SRE installed
  • EX8200-48T / EX8200-48T-ES: 48 Gbps
  • EX8200-48F / EX8200-48F-ES: 48 Gbps
  • EX8200-8XS / EX8200-8XS-ES: 80 Gbps
  • EX8200-40XS / EX8200-40XS-ES: 80 Gbps
  • EX8200-48PL / EX8200-48TL: 20 Gbps
  • EX8200-2XS-40P / EX8200-2XS-40T: 40 Gbps
  • EX9200-40T: Up to 40 Gbps
  • EX9200-40F: Up to 40 Gbps
  • EX9200-32XS: Up to 240 Gbps
  • EX9200-4QS: Up to 120 Gbps
Throughput
  • EX2200-24P/24T: 42 Mpps (wire speed)
  • EX2200-48P/48T: 77 Mpps (wire speed)
  • EX2200-C-12T/12P-2G: 21 Mpps
    EX3200-24P/24T: 65 Mpps (wire speed)
    EX3200-48P/48T: 101 Mpps (wire speed)
  • EX3300-24P/24T/24T-DC:
    95 Mpps (wire speed)
  • EX3300-48P/48T/48T-BF:
    130 Mpps (wire speed)
EX4200-24P/24T/24F: 65 Mpps (wire speed)
EX4200-48P/48T: 101 Mpps (wire speed)
EX4300-24P/24TF: 333 Mpps (wire speed)
EX4300-48P/48T: 369 Mpps (wire speed)
EX4300-32F: 345 Mpps (wire speed)
714 Mpps690 Mpps system throughput
  • 120 Mpps per line card (wire speed)
  • 960 Mpps (EX8208) or 1.92 Bpps (EX8216) per system

Up to 240 Gbps per slot (full duplex) on all chassis

10/100/1000BASE-T Port Densities

EX2200:

  • 24 / 48 per platform
  • Up to 96 / 192 in Virtual Chassis configuration

EX2200-C:

  • 14 per platform
  • Up to 56 in Virtual Chassis configuration
24 / 48 per platform

EX3300-24P/24T/24T:

  • 28 per platform (24 access ports + four uplink ports)
  • Up to 280 in Virtual Chassis configuration

EX3300-48P/48T/48T:

  • 52 per platform (48 access ports + four uplink ports)
  • Up to 520 in Virtual Chassis configuration
  • 24 / 48 per platform
  • Up to 480 in Virtual Chassis configuration
  • 24 / 48 per platform (EX4300-24P/T; EX4300-48P/T)
  • Up to 480 in Virtual Chassis configuration
EX4500
  • 40 1000BASE-T ports in base unit (48 total with optional uplink modules) via copper SFP optics
  • Up to 480 in Virtual Chassis configuration
EX4550:
  • 32 1000BASE-T ports in base unit (48 total with optional expansion modules) via copper SFP optics
  • Up to 400 in Virtual Chassis configuration
  • 432 per chassis (384 ports using dedicated I/O slots + 48 ports using optional SRE slot) (roadmap)
  • 1,296 per 42 U rack
  • 48 line rate (EX8200-48T line card) or 2.4:1 oversubscribed (EX8200-48TL /48PL line cards)
  • 384 (EX8208) or 768 (EX8216) PoE / non PoE per chassis
  • 1536 (EX8208) or 3072 (EX8216) in Virtual Chassis configuration
  • 96 (EX8208) or 192 (EX8216) PoE+ per chassis
  • EX9204: 120 (EX9200-40T line card)
  • EX9208: 240 (EX9200-40T line card)
  • EX9214: 480 (EX9200-40T line card)
100BASE-FX / 1000BASE-X (SFP) Port Densities

EX2200:

  • 4 per switch (fixed ports, SFP required)
  • Up to 16 in Virtual Chassis configuration

EX2200-C:

  • 2 per switch (fixed ports, SFP required)
  • Up to eight in Virtual Chassis configuration
4 per switch (via optional four-port GbE uplink module)
  • 4 per switch (fixed ports, SFP/SFP+ required)
  • Up to 40 in Virtual Chassis configuration
  • 24 per switch; 28 with optional four-port GbE uplink module
  • Up to 280 in Virtual Chassis configuration
EX4300-32F:
  • 44 per switch (36 in base unit plus 8 via optional eight-port 1GbE/10GbE uplink module)
  • Up to 440 in Virtual Chassis configuration

EX4300-24P/T and EX4300-48P/T:
  • 4 per switch (via optional four-port 1GbE/10GbE uplink module)
  • Up to 40 in Virtual Chassis configuration
EX4500:
  • 40 1000BASE-X SFP ports in base unit; 48 total with optional uplink modules
  • Up to 480 in Virtual Chassis configuration
EX4550:
  • 32 1000BASE-X SFP/SFP+ ports in base unit; 48 total with optional expansion modules
  • Up to 400 in Virtual Chassis configuration
  • 432 maximum per chassis (384 ports using dedicated I/O slots + 48 ports using optional SRE slot); 1,296 per 42 U rack
  • 392 per chassis (384 using dedicated I/O slots only + 8 using 1GbE/10GbE SFP/SFP+ uplink ports on SRE modules)
  • 48 per EX8200-48F line card
  • 384 (EX8208) or 768 (EX8216) per chassis
  • EX9204: 120 (EX9200-40F line card)
  • EX9208: 240 (EX9200-40F line card)
  • EX9214: 480 (EX9200-40F line card)
10GBASE-X Port DensitiesN/A2 per switch (via optional two-port 10GbE uplink module)
  • 4 per switch
  • Up to 40 in Virtual Chassis configuration
  • 2 per switch (via optional two-port 10GbE uplink module)
  • Up to 20 in Virtual Chassis configuration
EX4300-32F:
  • 12 per switch (4 in base unit plus 8 via optional eight-port uplink module)
  • Up to 120 in Virtual Chassis configuration

EX4300-24P/T and EX4300-48P/T:
  • 4 per switch (via optional four-port 1GbE/10GbE uplink module)
  • Up to 40 in Virtual Chassis configuration
EX4500:
  • 40 in base unit; 48 total with optional uplink modules
  • Up to 480 in Virtual Chassis configuration
EX4550:
  • 32 in base unit; 48 total with optional uplink modules
  • Up to 400 in Virtual Chassis configuration
8 1GbE/10GbE SFP/SFP+ uplink ports on SRE modulesLine Rate:
  • 8 per EX8200-8XS line card
  • 64 (EX8208) or 128 (EX8216) per chassis
  • 256 (EX8208) or 512 (EX8216) in Virtual Chassis configuration
Oversubscribed:
  • 40 per EX8200-40XS line card
  • 320 (EX8208) or 640 (EX8216) per chassis
  • 1,280 (EX8208) or 2,560 (EX8216) in Virtual Chassis configuration
  • EX9204: 96 (EX9200-32XS line card)
  • EX9208: 160 (EX9200-32XS line card)
  • EX9214: 320 (EX9200-32XS line card)
40GBASE QSFP+ Port DensitiesN/AN/AN/AN/A
  • 4 per switch
  • Up to 20 in Virtual Chassis configuration (assuming 2 ports per switch are used for forming Virtual Chassis)
N/AN/AN/A
  • EX9204: 12 (EX9200-4QS line card)
  • EX9208: 28 (EX9200-4QS line card)
  • EX9214: 48 (EX9200-4QS line card)
100GBASE CFP Port DensitiesN/AN/AN/AN/AN/AN/AN/AN/A
  • EX9204: 6 using EX9200-2C-8XS line card (future)
  • EX9208: 10 using EX9200-2C-8XS line card (future)
  • EX9214: 20 using EX9200-2C-8XS line card (future)
Resiliency
  • EX2200: Integral power supply and fans; external power supply option
  • EX2200-C: Fanless design improves MTBF by eliminating moving parts that can fail
Internal field-replaceable power supply; field-replaceable fanGraceful Route Engine Failover (GRES) in Virtual Chassis configuration; external power supply optionInternal, hot-swappable redundant power supply; field-replaceable fan tray with three fans; graceful Route Engine switchover (GRES) in Virtual Chassis configurationInternal, hot-swappable redundant power supply; field-replaceable fans; graceful Route Engine switchover (GRES) in Virtual Chassis configurationDual internal load sharing AC and DC power supplies (optional); redundant variable-speed fans4 power supply slots for N+1 or N+N (2+2) redundancy; redundant Routing Engines and Switch Fabrics; GRES6 power supply bays for N+1 or N+N redundancy; field-replaceable fan trays; redundant Routing Engines and Switch Fabrics; GRES4 power supply bays on each chassis for N+1 or N+N redundancy; field-replaceable fan trays; redundant Routing Engines and Switch Fabrics; graceful routing engine switchover
Power Options
  • EX2200-24T (non-PoE): Autosensing; 100-120 V / 200-240 V / 200-240 V; AC 50 W
  • EX2200-48T (non-PoE): Autosensing; 100-120 V / 200-240 V / 200-240 V; AC 470 W
  • EX2200-24P (PoE/PoE+): Autosensing; 100-120 V / 200-240 V / 200-240 V; AC 470 W
  • EX2200-48P (PoE/PoE+): Autosensing; 100-120 V / 200-240 V / 200-240 V; AC 496 W
  • EX2200-C-12T-2G (non-PoE): 100-120 V / 200-240 V; AC 30 W
  • EX2200-C-12P-2G (PoE/PoE+): 100-120 V / 200-240 V; AC 180 W
  • AC: 320W, 600W and 930W autosensing; 100-120V / 200-240V
  • DC: 190W; input voltage range 36V-72V; dual input feed
  • EX3300-24T/-48T/-48T-BF (non-PoE): Autosensing; 100-120 V / 200-240 V; AC 100 W
  • EX3300-24P (PoE/PoE+): Autosensing; 100-120 V / 200-240 V; AC 550
  • EX3300-48P (PoE/PoE+): Autosensing; 100-120 V / 200-240 V; AC 900
  • EX3300-24T-DC: Autosensing; 100-120 V / 200-240 V; DC 100 W
  • AC: 320W, 600W and 930W autosensing; 100-120V / 200-240V; dual load-sharing hot-swappable internal redundant power supplies
  • DC: 190W: input voltage range 36V-72V; dual input feed, dual load-sharing hot-swappable internal redundant power supplies
  • AC: 350W, 715W and 1100W autosensing; 100-120V / 200-240V; dual load-sharing hot-swappable internal redundant power supplies; front-to-back or back-to-front airflow
  • DC: 550W: input voltage range 36V-72V; dual input feed, dual load-sharing hot-swappable internal redundant power supplies; front-to-back or back-to-front airflow
EX4500:
  • 100-120 V AC: 1000 W
  • 200-240 V AC: 1200 W
  • 1200 W DC
EX4550:
  • 650 W AC and DC power supplies
  • AC: 2500W and 5000W (roadmap) autosensing
  • 100-120V / 200-240V (up to 10,000W or 20,000W per system) (roadmap)
  • DC: 2100W
  • AC: 1200W and 2000W autosensing; 100-120V / 200-240V (up to 6000W or 10,000W per chassis)
  • AC: 3000W 200-240V (up to 15,000W per chassis)
EX9204:
  • -40 to -72 V DC: 2,400 W
  • 100-120 V AC: 1,167 W
  • 200-240 V AC: 2,050 W

EX9208:
  • -40 to -72 V DC: 2,400 W
  • 100-120 V AC: 1,167 W
  • 200-240 V AC: 2,050 W

EX9214:
  • -40 to -72 V DC: 2,400 W
  • 200-240 V AC: 2,050W
Operating SystemJunosJunosJunosJunosJunosJunosJunosJunosJunos
Traffic MonitoringsFlowsFlow N/AsFlow sFlow sFlowsFlow (planned)sFlowsFlow
QoS Queues / Port8888128888
MAC Addresses16,00032,00016,00032,00064,00032,00032,000160,0001,000,000
Jumbo Frames9,216 Bytes9,216 Bytes9,216 Bytes9,216 Bytes9,216 Bytes9,216 bytes9216 Bytes9,216 Bytes9,192 Bytes
IPv4 Unicast / Multicast Routes6,500 / 100016,000 / 8,000 8,000 / 016,000 / 8,000 32,000 / 8,000 14,000*/ 4,000
*Uni-dimensional scale
10,000 / 4,000
  • Standard: 500,000 / 100,000
  • ES models: 1 million / 100,000
256,000
IPv6 Unicast / Multicast RoutesN/A4,000 / 2,000N/A4,000 / 2,00018,000 / 4,0003,400*/ 1,000
*Uni-dimensional scale
1,000 / 1,000
  • EX8208: 250,000 (500,000 with extra-scale line cards) / 100,000 (200,000 with extra-scale line cards)
  • EX8216: 250,000 (500,000 with extra-scale line cards) / 100,000 (200,000 with extra-scale line cards)
256,000
Number of VLANs1,0244,0964,0964,0964,0934,0964,0964,09632,000
ARP Entries2,00016,0004,00016,00064,0008,0008,000100,000256,000
Warranty
  • EX2200: Enhanced limited lifetime hardware warranty
  • EX2200-C: Enhanced limited lifetime hardware warranty
Limited lifetime switch hardware warranty Enhanced limited lifetime hardware warrantyLimited lifetime switch hardware warranty Limited lifetime switch hardware warrantyStandard one-year warrantyEnhanced limited lifetime hardware warrantyStandard one-year warrantyStandard one-year warranty